Metal corrugated pipe in high frequency and low amplitude vibration occasions. Due to the pressure pulse through the flowing medium is delivered to the bellows to go outside, not suitable for low frequency and high amplitude vibrations. Therefore, when the system vibration is caused by the pressure pulse, is not a set of bellows to eliminate. At the same time, if the vibration of the pipeline is due to excessive pressure pulse caused by, so, the add pipeline support and bundled reinforcement method is not.
In this case, in order to reduce these phenomena, corrugated tube should be set to the inner sleeve. Consider installing a buffer and shock absorber, so that a high amplitude low frequency vibration is converted to become less severe high frequency and low amplitude of pulse. In addition, also can be in high flow rates, occurs in the corrugated pipe turbulent flow and its internal turbulence can cause vibration.
In short, in the design of the corrugated tube lines, should ensure the system vibration frequency is not coincide and vibration load does not damage the function of corrugated pipe.